category:energy / date:2024-04-19 00:45:42 / browse:37 / comment:6
Kg to kg / m, and the steel plate thickness generally needs to be more than . mm to meet the standard. On the market, the main raw materials of special cold storage board for cold storage project are polyphenylene,HorabrenSmall cold storage installation company, polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin, and the thermal insulation coefficient is not very high; After a certain ratio of polyethylene, it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, and has high load-bearing capacity; Polyphenylene resin has strong water absorption but poor heat insulation. Therefore, the polyurethane sandwich board with very good performance belongs to the polyurethane sandwich board. Although it is slightly higher, the polyurethane board has very good thermal insulation performance and does not absorb moisture.Various construction materials, such as material certificate, test report and stage acceptance record, carefully, timely, accurately and comprehensively reflect the whole process of production and construction, and actively cooperate with the owner in design change and technical negotiation.Horabren,The suction pressure of fresh-keeping storehouse remains unchanged, and when the exhaust pressure increases,HorabrenCold storage engineering design and installation manufacturer, the exhaust temperature increases; If the exhaust pressure remains unchanged, when the suction pressure decreases, the exhaust temperature also increases. Both cases are caused by the increase of compression ratio of fresh-keeping warehouse. Too high condensation temperature and exhaust temperature of fresh-keeping warehouse are unfavorable to the operation of compressor, which should be prevented. Too high exhaust temperature will dilute the oil and even carbonize and coke, which will worsen the compressor conditions of the fresh-keeping warehouse.Whether the parameters of refrigeration equipment are consistent. When the cold storage leaves the factory, the temperature and temperature difference parameters of the cold storage shall be customized according to the user's requirements. After understanding the technical parameters of the cold storage, set the parameters on the refrigerator. During use the air humidity is high and the defrosting interval is long. The common cold storage boards of cold storage include mm, mm, mm and mm polyurethane thermal insulation boards,HorabrenCold storage and fresh storage, color steel tiles, salt thick steel plates, embossed aluminum plates, etc. on both sides or single and double sides, more general color steel tiles are produced and processed into hidden grooves, which have light weight, high compressive strength, good fire resistance corrosion resistance and aging resistance, and is a wide range of raw materials selected for the heat insulation and heat preservation of the cold storage. The cost of stainless steel plate and salt plate increases, and it is also easy to deform and damage the appearance.Mutare,Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, the length and height width ratio of the cold storage shall be determined. Necessary auxiliary engineering buildings and equipment shall also be considered in the design of cold storage, such as working intermediate, packaging and combing room, special tool warehouse, loading and unloading platform, etc.Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, and unqualified products are not allowed to leave the factory.Pay attention to the energy saving of the lighting system: the lighting of the cold storage should be considered comprehensively according to the area, height and warehouse temperature of the cold storage on the basis of safety, science and rationality, from the perspective of energy saving and environmental protection. The lighting in the cold storage is concentrated in the working area.
Stretch perlite: stretch perlite is a kind of granular material with porous layout. The gap in it blocks out the heat. Professional cold storage installation, cold storage installation, cold storage construction, fruit fresh-keeping cold storage, medical cold storage, strict testing, quality assurance. Preferential activities are in progress. Welcome to consult. It has a good heat insulation effect. Then, the water vapor in the cold storage is easy to condense, and the water absorption of extensional perlite is particularly strong. If it absorbs a lot of water, its nature will be greatly reduced. Therefore, it is necessary to be careful to select extensional perlite as cold storage.The volume of cold storage the size of cold storage shall be calculated according to the volume occupied by the stacking of goods stored in the cold storage plus the corridor from row to row, the indoor space between the stack and the wall, and the gap between the ceiling and the packaging room. After determining the volume, the length width ratio of the cold storage shall be determined. When designing the cold storage, necessary auxiliary engineering buildings and equipment should also be considered, such as working intermediate, packaging and combing room, special tool warehouse and loading and unloading platform so as to ensure the quality of the cold storage.The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.Good reputation,Acid disinfectant can be used for mold removal and disinfection of quick-frozen warehouse.Insufficient refrigeration dose and capacity in the system: there are two main reasons for insufficient refrigerant circulation,More and more people begin to build cold storage, and most people choose to use cold storage for cold storage construction. Why? Why do people choose cold storage for construction? What are the advantages of cold storage? The following is a detailed introduction.
What should be considered in building a cold storage? In these aspects, food cold storage is a systematic project of artificial refrigeration to ensure food quality and reduce food decay in a low-temperature environment. Refrigeration technology affects the design of food cold storage, meets the needs of refrigeration technology, convenient production, energy saving and cost reduction. What problems should be considered in the construction of food cold storage?Sampling inspection,It is strictly prohibited to place articles with pollution and peculiar smell around the cold storage. The surrounding environment of the cold storage must be cleaned and disinfected regularly every day, and the door of the cold storage must be locked.Reasonably design the division of fresh-keeping warehouse, such as cold storage room, freezer room, machine room, aisle, transportation platform, a sunshade shall be built; Wires shall not be outdoors,Now let's analyze the production and use requirements of the cold storage. There is no condensation in the cold storage. Condensation in the cold storage or in the insulation layer is harmful. During the drying process of the new wall or under winter conditions when the water vapor with high indoor temperature migrates outdoors, it is impossible to condense in the wall due to the obstruction of the cold storage.Horabren,During the production of cold storage, the cold storage will produce fixed length, width and thickness according to the needs of various cold storage projects. Generally, cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, use cm or cm thick library board. When you budget the cold storage project, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to regulations, the foaming density of cold storage is per cubic meterImmediate cooling is to install the condenser of the cold storage in the box or building of the cooling equipment, use the volatilization of the refrigerant to immediately cool the air in the air, and use the cold air to cool the objects that need to be cooled. This kind of refrigeration is characterized by faster cooling speed, small heat conduction temperature difference and simple system software, so it is widely used.Installation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse, the distance between the box bottom and the top of the warehouse must be & amp; gt; mm; The electrical box can be fixed on the building wall or on the angle steel frame.
share 6 Comments
Comment / Cancel reply